Specifications and technology / Intruder alarms
A zone identifies a monitored point or logical input. A partition groups part of the system for arming and disarming. A wired loop is a physical circuit connecting devices. Manufacturers may use different terms, so read capacity figures alongside their definitions.
Why use partitions?
In a shop, the sales floor may remain open after the stockroom is armed. This requires separate partitions, appropriate user permissions and a defined operating mode for the shared corridor. Ajax describes independent group control and user access to individual groups. The number of partitions can differ from the number of rooms in the app.
Why detector count differs from input count
One input on a wired panel can represent a circuit with several contacts. The circuit design then determines how precisely the system locates an event. For maintenance, it helps to know which device or line needs attention, in addition to knowing that the stockroom is in alarm. Consider fault diagnosis before combining devices to save inputs.
| Term | Practical meaning |
|---|---|
| Zone | Individual monitored point or input |
| Partition | Part of the system with its own arming state |
| Wired loop | Physical circuit connecting wired devices |
| EOL | Circuit state supervision by resistance |
What an EOL resistor does
A supervised input distinguishes states by circuit resistance. Support for NO, NC, EOL, 2EOL and 3EOL depends on the hardware and firmware. Ajax lists the supported options for MultiTransmitter. Use the resistance values and positions specified in the manufacturer’s diagram. An EOL label alone does not guarantee identical fault detection across systems.
Planning a small site
List the doors, rooms and users. For each point, specify when it must be armed and who may disarm it. Define the shared entrance separately so that an office employee does not inadvertently disarm the warehouse. Then calculate the required zones, partitions and expansion modules, leaving room for growth.
Testing operating modes
Test arming each partition, access for different users and passage through shared areas. The installer should test wired circuit faults according to the manual. Keep a record mapping inputs to meaningful names. A label such as “input 7” will be hard to diagnose a year later.
Checks before choosing
- Define arming states and permissions before counting devices.
- Check the capacity of the main panel and expansion modules.
- Test partitions and shared passages with actual users.
Capacity, expansion and notifications
Wireless devices, zones, users and controllable outputs have separate limits. A panel output controls an external device, while an input receives a signal. Expansion usually requires compatible modules. A figure in brackets may indicate the system maximum rather than what is included. Also check keypad compatibility, permissions and accessible partitions.
A standalone installation can respond locally and notify the owner. A monitored installation also reports events to a monitoring company using an agreed protocol and service. Communication channels vary by panel.
Push notifications, SMS and calls have different delivery requirements. The number of permitted telephone or SMS recipients describes list capacity. It does not specify how many calls can be placed simultaneously. Check recipient permissions, cellular service, the plan and app permissions, then test an alarm. The Ajax Hub 2 manual describes users, devices and notifications separately. Other alarm panels may have different limits.
Keypads and partition control
External keypad count is a separate panel limit. A keypad built into a code reader need not provide the same controls. Mechanical buttons and touch panels describe the user interface, not how many partitions are available. For each user, check which partitions they can control, how alarms appear and what happens if communication fails.
“Zones / groups” on an amplifier or microphone may refer to public address zones. Alarm loop rules do not apply to them. Fire alarm systems likewise have their own definitions and configuration limits.
Frequently asked questions
Is a room in the app an alarm partition?
Not necessarily. A room may simply organise devices in the app.
Do more zones mean more independently controlled partitions?
No. They are separate system limits.
Can I use any EOL resistor?
No. The value and circuit must match the input and its configuration.
In brief
Plan the alarm around how each space is used. Count zones, partitions and wired loops separately.